Bettis Electric Actuators: XTE3000 & M2CP

Current Bettis Models for New Valves and Legacy EIM Replacements

If you need a current replacement for an EIM actuator, an electric actuator for a valve with no instrument air nearby, or help sizing a spec, TRIVACO can handle it. TRIVACO is an authorized Emerson distributor for Bettis electric actuators in Kentucky, Ohio, and Indiana, including the XTE3000 and the M2CP. The M2CP is the current model in the EIM Series 2000 line, so it fits sites already running EIM units.

Where Electric Actuator Orders Get Stuck

We can address every one of these at the quoting stage.

Bettis Electric Actuators We Supply

An electric actuator uses a motor to open and close a valve on a signal from your control system. Both models below handle on/off service on isolation valves, with ratings for multi-turn, quarter-turn, and linear valves. The XTE3000 also handles control duty.

Bettis XTE3000 Electric Actuator

The XTE3000 is a non-intrusive multi-turn actuator that Emerson built for oil and gas, power, and process plants. Setup and diagnostics happen through the closed cover.

  • Push-button and Bluetooth® setup. Operate, configure, and run diagnostics with the control compartment sealed.
  • Position after a power loss. The absolute encoder reads valve position even when main and backup power are lost.
  • Recorded maintenance data. The datalogger keeps operating data, alarms, and valve torque curves for review in Emerson’s DCMlink software.
  • Declutchable manual override. On an electrical command, an internal spring-loaded clutch disengages the handwheel and re-engages the motor drive. The handwheel won’t spin under motor power, which protects the technician.
  • Fieldbus options. Modbus®, HART®, FOUNDATION™ Fieldbus, PROFIBUS, and LonWorks®.

Bettis M2CP Electric Valve Actuator

The M2CP is a conventional, heavy-duty actuator with the same mechanical design as the EIM Series 2000. Emerson built it for harsh service and field repair.

  • Screwdriver service. The control package comes out, comes apart, and goes back in with a standard screwdriver.
  • Hand operation on a seated valve. A power shift clutch moves the M2CP to handwheel operation with little force. The clutch handle padlocks in hand or motor position.
  • Motor options. Most single-phase and three-phase AC voltages, plus DC.
  • Shock and vibration. Meets DOD-V-24657(SH) high shock and MIL-STD-167-1 and MIL-STD-901D mechanical vibration standards.
  • Network options. Modbus, HART, FOUNDATION Fieldbus, PROFIBUS, DeviceNet™, and Ethernet.

Bettis XTE3000 vs. M2CP Specifications

The main split between the two models is design style. The XTE3000 is non-intrusive, with sealed compartments and on-device setup. The M2CP is conventional, with point-to-point wiring and a field-serviceable control package.
Spec
Bettis XTE3000
Bettis M2CP
Design style
Non-intrusive
Conventional
Service
On/off and control
On/off
Multi-turn torque
Up to 57,000 Nm (42,000 lbf-ft)
Up to 21,693 Nm (16,000 lbf-ft)
Quarter-turn torque
Up to 1,000,000 Nm (737,500 lbf-ft)
Up to 370,000 Nm (273,000 lbf-ft)
Linear force
Up to 150 kN (33,720 lb)
Up to 2,224 kN (500,000 lb)
Power supply
Three-phase AC, single-phase AC, DC; not available above 600 V
Most single-phase and three-phase AC voltages, plus DC
Enclosure
IP66/IP68 (IEC 60529)
NEMA 4, 4X, 6, 7, and 9; optional IP68 submersible, 20 ft (6 m) for 72 hrs [CONFIRM #1]
Ambient temperature
-20 to 85 °C (-4 to 185 °F) standard; -40 °C and -60 °C low-temperature options
-30 to +70 °C standard; -50 to +60 °C optional [CONFIRM #1]
Hazardous area approvals
FM and CSA; ATEX (Directive 2014/34/EU)
FM and CSA Class I, II, III Division 1; ATEX; IECEx [CONFIRM #1]
Communication protocols
Modbus, HART, FOUNDATION Fieldbus, PROFIBUS, LonWorks
Modbus, HART, FOUNDATION Fieldbus, PROFIBUS, DeviceNet, Ethernet
Setup and diagnostics
Local push-button panel, Bluetooth, DCMlink
DCMlink (M2CP 320B control)
Manual operation
Declutchable handwheel; a spring-loaded clutch re-engages the motor on an electrical command, and the handwheel doesn't spin under motor power
Power shift clutch and handwheel; clutch padlocks in hand or motor position
Torque and force values are Emerson’s published maximums for each model family. Your valve’s torque, stroke, and speed decide the actual size. Full data sheets are in the Resources section below.

Choose the XTE3000 for On-Device Setup and Diagnostics

The XTE3000 suits plants that want local configuration, Bluetooth access, recorded torque curves, and DCMlink diagnostics.

Choose the M2CP for Severe Service or an Existing EIM Fleet

Emerson notes that conventional designs generally suit severe service with extreme vibration or temperature. The M2CP also fits sites already running EIM Series 2000 actuators, since it carries the same mechanical design.

Replacing EIM M2CP and MCP Actuators

The Bettis M2CP is the EIM M2CP under the Bettis name. It keeps the Series 2000 mechanical design that dates to 1979. Many parts interchange across the M2CP and Series 2000 range, so upgrades often fit units already in service. For the EIM MCP, which Emerson discontinued in 2018, the Bettis M2CP is the listed replacement.

Replacing an EIM unit? Email a photo of the nameplate to [email protected]. We’ll quote the Bettis model that fits your valve.

Buying for resale? We supply Bettis electric actuators through the distribution channel, as loose actuators or as complete automated valve assemblies.

Where Bettis Electric Actuators Are Used

Oil and Gas Transmission

Isolation valves at compressor stations and on natural gas and liquids pipelines. Emerson designed the XTE3000 for oil and gas service.

Power Generation (Fossil and Hydro)

Steam, water, and fuel isolation valves. Emerson’s M2CP brochure shows an M2CP with a bevel gear in 1,070 °F (577 °C) steam service at a power plant.

Chemical Process and Refineries

The XTE3000 manual lists heavy industrial, chemical, and petrochemical plants. Emerson also offers a Coker variant of the M2CP built for extended vibration.

Tank Farms

Remote open and close of tank and manifold isolation valves, tied into your control system over Modbus or another supported network.

Municipal Water and Wastewater Treatment

Valves in vaults and pits that can flood. The M2CP offers optional IP68 submersible service. Emerson’s AquaNaught variant of the M2CP handles extended submersion.

Steel, Aluminum, and Pulp and Paper

Heavy plants with heat, dust, and vibration, where a conventional design like the M2CP is often the better fit.

Sizing a Bettis Electric Actuator

What to send with your quote request:

  • Valve type and stroke. Multi-turn (gate, globe), quarter-turn (ball, butterfly, plug), or linear. For multi-turn valves, include the number of turns.
  • Torque or thrust. Give the valve’s required operating torque or thrust. Emerson’s XTE3000 data sheet notes that stall torque can reach 2 times nominal torque, depending on speed and voltage. Check that the valve stem and mounting can take that load.
  • Duty cycle. Opening and closing an isolation valve is short-time duty (S2). Modulating duty (S4) runs up to 1,200 starts per hour. Emerson notes that an under-specified duty cycle hurts performance, while an over-specified one adds cost.
  • Operating time. How fast the valve has to stroke open or closed.
  • Power supply. Voltage, phase, and frequency, or DC. The XTE3000 isn’t available above 600 V.
  • Controls. Hardwired signals or the network protocol your system uses.
  • Area classification and ambient temperature. The hazardous-area class and division (or zone), plus the site’s low and high temperatures.

Already Have EIM or Bettis Actuators in Service?

TRIVACO supplies the actuator alone or as part of a complete automated valve assembly. Our team mounts the actuator to your valve, tests the assembly, and supports startup in the field. Our Valve Repair Shop and Field Service and Installation team also work on EIM and Bettis units already in your plant. For networks of actuators, our UL Panel Shop builds the control panels that tie them to your system.

TRIVACO has been selling and servicing electric actuators for over 35 years.

Warranty: Bettis actuators carry a standard 12-month warranty from the date of shipment.

Resources

Also From TRIVACO

Need the valve as well? Our Valves and Automation category covers the isolation valves, control valves, and pneumatic actuators we pair with electric units. For overpressure protection on the same lines, see Safety Valves & Pressure Relief Devices.

Safety Valve Questions We Get Asked

What is a Bettis electric actuator used for?
A Bettis electric actuator opens and closes an industrial valve on a signal from your control system. It takes the place of a handwheel or a pneumatic operator on gate, globe, ball, butterfly, and plug valves. Plants use them for isolation duty in pipelines, power plants, refineries, tank farms, and water treatment.
The XTE3000 is a non-intrusive actuator. You set it up through a push-button panel or Bluetooth with the cover closed. It also logs torque curves and alarms for diagnostics. The M2CP is a conventional design with point-to-point wiring, a field-serviceable control package, and a track record in severe service going back to 1979.
Yes. Emerson rebranded the EIM M2CP as the Bettis M2CP. It keeps the same mechanical design as the EIM Series 2000, which dates to 1979. Emerson’s brochure says many parts interchange across the M2CP and Series 2000 range. Emerson also describes control upgrades on existing units as easy to retrofit.
Emerson discontinued the EIM MCP in 2018 after nearly 50 years of service. Emerson lists the Bettis M2CP as its replacement. Send TRIVACO the nameplate data from your MCP, including model, torque, and voltage. We’ll confirm the matching M2CP and any mounting changes your valve needs.
Usually, if we know the dates. Send us the tag list and the window and we will tell you what fits and what needs a replacement unit ordered instead. For valves that cannot come off the unit, our mobile VR trailer runs the same certified process on your site. 
The XTE3000 supports Modbus, HART, FOUNDATION Fieldbus, PROFIBUS, and LonWorks. The M2CP supports Modbus, HART, FOUNDATION Fieldbus, PROFIBUS, DeviceNet, and Ethernet. Both work with Emerson’s DCMlink software for configuration and diagnostics. Emerson’s Controlinc network master can control and monitor up to 250 actuators from one panel.
Emerson lists both models as certified explosion-proof and weatherproof. The XTE3000 carries FM and CSA approvals. The M2CP carries FM and CSA approvals for Class I, II, and III, Division 1 locations, plus ATEX and IECEx. Share your area classification so TRIVACO can confirm the right certificate for your site.
We carry some M2CP actuators and parts in stock. Other configurations ship from the factory, with a typical lead time of 8 to 10 weeks. Lead time depends on the model, size, motor, and control options. Your quote lists the expected ship date so you can plan around your outage.
Yes. Our Valve Repair Shop and field service team work on EIM and Bettis units already in service. If a unit is past repair, we match it to a current Bettis model from the nameplate data. Call 800.500.8880 to schedule work on actuators in your plant.
Price depends on valve size, torque, motor voltage, controls, and certifications. A small quarter-turn on/off unit usually costs less than a large multi-turn unit with a fieldbus card. TRIVACO configures each actuator to the valve, so we quote each job. Send your valve details for a written quote and lead time.

Request a Quote for Bettis Electric Actuators

Tell us about the valve and how you control it. TRIVACO turns quotes around the same day or the next day, with a sized recommendation, a written quote, and a lead time. If you’re replacing an EIM unit, attach a photo of the nameplate.